Forumlongevatech.com - investigation · Shop talk · 4 replies

GHRP-6 10mg lab test from Certified Peptides, December 2025

Vanguard Laboratory tested GHRP-6 10mg from Certified Peptides on Dec 15, 2025. It measured 98.46% purity and 9.4 mg against 10 mg on the label.

HPLC purity
98.46%
✓ Excellent
Excellent means 98% or higher.
In the vial
9.4 mgThe label says 10 mg, so 6% less.
Tested on
Lot
251125GP103
See the certificate ↓

Not checked on Vanguard Laboratory's portal

This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)98.46%How much of what's in the vial is the target compound
Amount in the vial9.4 mglabel says 10 mg · 6% lessWhether you get the amount on the label
Endotoxin< 0.05 EU/mgIs it safe to inject? Checks for bacterial toxins
ContainerSmall vial with flip-off cap / Printed label
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 9.4 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 6% less means in a syringe

94% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.4 mg using the measured mass, against 2.5 mg on the label — 6% less.

Certificate of analysis

Original document
Issued by Vanguard Laboratory · Dec 15, 2025 · Batch 251125GP103

About this test

How this certificate was checked

Report number251125GP103
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Certified Peptides' Trust Score until Dec 15, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Mar 11, 2026
Summary

Independent HPLC purity analysis of GHRP-6 from Certified Peptides, performed by Vanguard Laboratory on December 15, 2025. Reported purity: 98.46%. Net content: 9.4 mg against 10 mg labeled (94% of label). Endotoxins: <0.05 EU/mg. Batch 251125GP103. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.