GHK-Cu / KPV lab test from Phase One Labz, July 2026
Freedom Diagnostics tested GHK-Cu / KPV from Phase One Labz on Jul 31, 2026. It measured 99.84% purity. The amount wasn't recorded.
- Tested by
- Freedom Diagnostics
- Tested on
- Lot
- P1-BTY06
Confirmed on Freedom Diagnostics' portal · checked Jul 31, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
Phas2607280192Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
Phase One Labz reviews and all 33 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.84% | How much of what's in the vial is the target compound |
| Endotoxin | 50.00 EU/mL · pass | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | ICP-MS: Arsenic, Cadmium, Lead, and Mercury below reporting/specification limits — Pass | Could there be metal contamination? |
| Container | Blue Lyophilized Powder | |
| Amount measured | Not recorded | Whether you get the amount on the label |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: the amount in the vial and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 2607280192 |
|---|---|
| On the lab's portal | ✓ Confirmed Aug 25, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Phase One Labz's Trust Score until Jul 31, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Aug 25, 2026 |
Independent HPLC purity analysis of GHK-Cu / KPV from Phase One Labz, performed by Freedom Diagnostics on July 31, 2026. Reported purity: 99.84%. Endotoxins: Pass — Assay Sensitivity: 50.00 EU/mL. Heavy metals: ICP-MS: Arsenic, Cadmium, Lead, and Mercury below reporting/specification limits — Pass. Batch P1-BTY06. Sample source: shop-provided. Certificate of analysis attached.