Epithalon 20mg lab test from BioLongevity Labs, lot N/A, January 2026
MDx BioAnalytical Laboratory tested Epithalon 20mg from BioLongevity Labs on Jan 15, 2026. It measured 99.76% purity and 21.33 mg against 20 mg on the label.
- In the vial
- 21.33 mgThe label says 20 mg, so 7% more.
- Tested by
- MDx BioAnalytical Laboratory
- Tested on
Not checked on MDx BioAnalytical Laboratory's portal
This certificate carries no lookup code. MDx BioAnalytical Laboratory has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 292 Epithalon lab tests →Epithalon pricesBioLongevity Labs reviews and all 152 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.76% | How much of what's in the vial is the target compound |
| Amount in the vial | 21.33 mglabel says 20 mg · 7% more | Whether you get the amount on the label |
| Endotoxin | < 0.05 EU/mL · pass | Is it safe to inject? Checks for bacterial toxins |
| Container | White crystals | |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 20 mg · Lab measured 21.33 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 7% more means in a syringe
107% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 5.3 mg using the measured mass, against 5 mg on the label — 7% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | N/A |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validMDx BioAnalytical Laboratory's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward BioLongevity Labs' Trust Score until Jan 15, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed May 11, 2026 |
Independent HPLC purity analysis of Epithalon from BioLongevity Labs, performed by MDx BioAnalytical Laboratory on January 15, 2026. Reported purity: 99.76%. Net content: 21.33 mg against 20 mg labeled (107% of label). Endotoxins: <0.05 EU/mL (PASS). Batch N/A. Sample source: shop-provided. Certificate of analysis attached.
Other lots of Epithalon from BioLongevity Labs
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| 9-3-46071 | Feb 20, 2026 | MDx BioAnalytical Laboratory | 99.73% | 102% of label | Not checked |
| 9-3-46035 | Jan 22, 2026 | BioRegen | 99.73% | 115% of label | Not checked |
| 9-2-45881 | Aug 26, 2025 | BioRegen | 99.7% | 97% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 291 other Epithalon tests on Peptigrity have a typical purity of 99.58%. This one is 99.76%.

Community discussion