Forumlongevatech.com - investigation · Shop talk · 4 replies

Epithalon 10mg lab test from Ascension Peptides, May 2026

Kovera Labs tested Epithalon 10mg from Ascension Peptides on May 23, 2026. It measured 99.312% purity and 9.64 mg against 10 mg on the label.

HPLC purity
99.312%
✓ Excellent
Excellent means 98% or higher.
In the vial
9.64 mgThe label says 10 mg, so 4% less.
Tested by
Kovera Labs
Tested on
Lot
15-05260628
See the certificate ↓

Confirmed on Kovera Labs' portal · checked May 23, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup code5GSZLSD

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.312%How much of what's in the vial is the target compound
Amount in the vial9.64 mglabel says 10 mg · 4% lessWhether you get the amount on the label
Endotoxin≤ 0.5 EU/mL · passIs it safe to inject? Checks for bacterial toxins
Heavy metalsArsenic, Cadmium, Lead, Mercury all NegativeCould there be metal contamination?
ContainerLyophilized Powder / Red Cap / Silver Crimp
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 10 mg · Lab measured 9.64 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 4% less means in a syringe

96% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.4 mg using the measured mass, against 2.5 mg on the label — 4% less.

Certificate of analysis

Original document
Issued by Kovera Labs · May 23, 2026 · Batch 15-05260628

About this test

How this certificate was checked

Report numberKVR-2026-A36FF4
On the lab's portal✓ Confirmed Jul 23, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Ascension Peptides' Trust Score until May 23, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jul 23, 2026
Summary

Independent HPLC purity analysis of EPITHALON from Ascension Peptides, performed by Kovera Labs on May 23, 2026. Reported purity: 99.312%. Net content: 9.64 mg against 10 mg labeled (96% of label). Endotoxins: PASS (≤0.5 EU/mL). Heavy metals: Arsenic, Cadmium, Lead, Mercury all Negative. Batch 15-05260628. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.