CJC-1295 with DAC 5mg lab test from Uther, February 2026
Janoshik Labs tested CJC-1295 with DAC 5mg from Uther on Feb 10, 2026. It measured 99.541% purity and 6.23 mg against 5 mg on the label.
- In the vial
- 6.23 mgThe label says 5 mg, so 25% more.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- CJWD5-0129
Confirmed on Janoshik Labs' portal · checked Feb 10, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
TXU9D2CHULNGSample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 121 CJC-1295 with DAC lab tests →CJC-1295 with DAC pricesUther reviews and all 259 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.541% | How much of what's in the vial is the target compound |
| Amount in the vial | 6.23 mglabel says 5 mg · 25% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 5 mg · Lab measured 6.23 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 25% more means in a syringe
125% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.6 mg using the measured mass, against 1.3 mg on the label — 25% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 105825 |
|---|---|
| On the lab's portal | ✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Submitted via | Shop panel (bulk upload) |
| Counts as | One lab testCounts toward Uther's Trust Score until Feb 10, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | @uther 👑 Legend |
Independent HPLC purity analysis of CJC-1295 with DAC from Uther, performed by Janoshik Labs on February 10, 2026. Reported purity: 99.541%. Net content: 6.23 mg against 5 mg labeled (125% of label). Tested content exceeds the labeled amount by 25%. Batch CJWD5-0129. Sample source: shop-provided. Certificate of analysis attached.
Other lots of CJC-1295 with DAC from Uther
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| CJWD5-0521 | Jun 8, 2026 | Janoshik Labs | 99.143% | 115% of label | Not checked |
| CJWD50808 | Aug 20, 2025 | Janoshik Labs | 99.072% | 112% of label | ✓ Confirmed |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.