CJC-1295 with DAC lab test from Peptide Maxxing, February 2026
Janoshik Labs tested CJC-1295 with DAC from Peptide Maxxing on Feb 17, 2026. It measured 99.405% purity and 5.04 mg against 5 mg on the label.
- In the vial
- 5.04 mgThe label says 5 mg, so 1% more.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- CJC583
Confirmed on Janoshik Labs' portal · checked Feb 17, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
U4SZ61Y7FPDSSample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 121 CJC-1295 with DAC lab tests →CJC-1295 with DAC pricesPeptide Maxxing reviews and all 39 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.405% | How much of what's in the vial is the target compound |
| Amount in the vial | 5.04 mglabel says 5 mg · 1% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 5 mg · Lab measured 5.04 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 1% more means in a syringe
101% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.3 mg using the measured mass, against 1.3 mg on the label — 1% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | #107542 |
|---|---|
| On the lab's portal | ✓ Confirmed Jul 28, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Peptide Maxxing's Trust Score until Feb 17, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 28, 2026 |
Independent HPLC purity analysis of CJC-1295 with DAC from Peptide Maxxing, performed by Janoshik Labs on February 17, 2026. Reported purity: 99.405%. Net content: 5.04 mg against 5 mg labeled (101% of label). Batch CJC583. Sample source: shop-provided. Certificate of analysis attached.
Other lots of CJC-1295 with DAC from Peptide Maxxing
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| CJC753 | May 29, 2026 | Freedom Diagnostics | 99.86% | 119% of label | ✓ Confirmed |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 120 other CJC-1295 with DAC tests on Peptigrity have a typical purity of 99.40%. This one is 99.405%.

Community discussion