Cardiogen 20mg lab test from PeptideTech, April 2026
Freedom Diagnostics tested Cardiogen 20mg from PeptideTech on Apr 27, 2026. It measured 99.85% purity and 20.7 mg against 20 mg on the label.
- In the vial
- 20.7 mgThe label says 20 mg, so 3% more.
- Tested by
- Freedom Diagnostics
- Tested on
- Lot
- CRD-3890
Confirmed on Freedom Diagnostics' portal · checked Apr 27, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
Pept2604270091Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 19 Cardiogen lab tests →Cardiogen pricesPeptideTech reviews and all 80 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.85% | How much of what's in the vial is the target compound |
| Amount in the vial | 20.7 mglabel says 20 mg · 3% more | Whether you get the amount on the label |
| Endotoxin | ≤ 0.05 EU/mL · pass | Is it safe to inject? Checks for bacterial toxins |
| Container | White Lyophilized Powder | |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 20 mg · Lab measured 20.7 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 3% more means in a syringe
103% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 5.2 mg using the measured mass, against 5 mg on the label — 4% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 2604270091 |
|---|---|
| On the lab's portal | ✓ Confirmed Aug 17, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward PeptideTech's Trust Score until Apr 27, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Aug 17, 2026 |
Independent HPLC purity analysis of Cardiogen from PeptideTech, performed by Freedom Diagnostics on April 27, 2026. Reported purity: 99.85%. Net content: 20.7 mg against 20 mg labeled (103% of label). Endotoxins: Pass (Assay Sensitivity: ≤0.05 EU/mL). Batch CRD-3890. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 18 other Cardiogen tests on Peptigrity have a typical purity of 99.61%. This one is 99.85%.

Community discussion