COA KVR-2026-D0B5EF matches Kovera Labs's public record. So this test doesn't rest on our review alone — the lab confirms it too.
E0KZjEbMThis is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Independent HPLC purity analysis of Cagrilintide from ascend.science peptides, performed by Kovera Labs on July 9, 2026. Reported purity: 99.643%. Net content: 11.28 mg against 10 mg labeled (113% of label). Tested content exceeds the labeled amount by 13%. Heavy metals: Arsenic (As): Negative, Cadmium (Cd): Negative, Lead (Pb): Negative, Mercury (hg): Negative. Batch C194H13Z1S405992. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.