Forumlongevatech.com - investigation · Shop talk · 4 replies

AOD-9604 5mg lab test from Peptide Foundry, July 2026

ILS Laboratories tested AOD-9604 5mg from Peptide Foundry on Jul 19, 2026. It measured 99.49% purity and 5.13 mg against 5 mg on the label.

HPLC purity
99.49%
✓ Excellent
Excellent means 98% or higher.
In the vial
5.13 mgThe label says 5 mg, so 3% more.
Tested on
Lot
FO108
See the certificate ↓

Confirmed on ILS Laboratories' portal · checked Jul 19, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup code8BMLN2TM

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.49%How much of what's in the vial is the target compound
Amount in the vial5.13 mglabel says 5 mg · 3% moreWhether you get the amount on the label
Endotoxin≤ 0.05 EU/mLIs it safe to inject? Checks for bacterial toxins
Heavy metalsAs .345 ppm; Pb .198 ppm; Cr 1.338 ppmCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 5 mg · Lab measured 5.13 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 3% more means in a syringe

103% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.3 mg using the measured mass, against 1.3 mg on the label — 3% more.

Certificate of analysis

2 original documents
Issued by ILS Laboratories · Jul 19, 2026 · Batch FO108

About this test

How this certificate was checked

Report numberCOA-2026-U2BZP
On the lab's portal✓ Confirmed Sep 1, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validILS Laboratories' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Peptide Foundry's Trust Score until Jul 19, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 01 · Peptigrity team · filed Sep 1, 2026
Summary

Independent HPLC purity analysis of AOD-9604 from Peptide Foundry, performed by ILS Laboratories on July 19, 2026. Reported purity: 99.49%. Net content: 5.13 mg against 5 mg labeled (103% of label). Endotoxins: NMT 0.05 EU/mL. Heavy metals: As .345 ppm; Pb .198 ppm; Cr 1.338 ppm. Batch FO108. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.