AOD-9604 5mg lab test from BioEdge Research Labs, August 2026
Kovera Labs tested AOD-9604 5mg from BioEdge Research Labs on Aug 3, 2026. It measured 99.394% purity and 5.1 mg against 5 mg on the label.
- In the vial
- 5.1 mgThe label says 5 mg, so 2% more.
- Tested by
- Kovera Labs
- Tested on
- Lot
- 062026AOD5M
Confirmed on Kovera Labs' portal · checked Aug 3, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
I8K53GMSample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 159 AOD-9604 lab tests →AOD-9604 pricesBioEdge Research Labs reviews and all 104 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.394% | How much of what's in the vial is the target compound |
| Amount in the vial | 5.1 mglabel says 5 mg · 2% more | Whether you get the amount on the label |
| Endotoxin | ≤ 0.5 EU/mL · pass | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | As, Cd, Pb, Hg — all Negative | Could there be metal contamination? |
| Container | Lyophilized Powder | |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.
What’s in the vial
Label 5 mg · Lab measured 5.1 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 2% more means in a syringe
102% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.3 mg using the measured mass, against 1.3 mg on the label — 2% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | KVR-2026-27B916 |
|---|---|
| On the lab's portal | ✓ Confirmed Aug 14, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward BioEdge Research Labs' Trust Score until Aug 3, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Aug 14, 2026 |
Independent HPLC purity analysis of AOD-9604 from BioEdge Research Labs, performed by Kovera Labs on August 3, 2026. Reported purity: 99.394%. Net content: 5.1 mg against 5 mg labeled (102% of label). Endotoxins: Pass (≤0.5 EU/mL). Heavy metals: As, Cd, Pb, Hg — all Negative. Batch 062026AOD5M. Sample source: shop-provided. Certificate of analysis attached.
Other lots of AOD-9604 from BioEdge Research Labs
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| 032526AOD5M | Apr 13, 2026 | Kovera Labs | 99.844% | 117% of label | ✓ Confirmed |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 158 other AOD-9604 tests on Peptigrity have a typical purity of 99.63%. This one is 99.394%.

Community discussion