Forumlongevatech.com - investigation · Shop talk · 4 replies

AHK-Cu lab test from Regenerative Research Peptides, November 2025

Krause Analytical tested AHK-Cu from Regenerative Research Peptides on Nov 10, 2025. It measured 99.07% purity and 93.4 mg against 100 mg on the label.

HPLC purity
99.07%
✓ Excellent
Excellent means 98% or higher.
In the vial
93.4 mgThe label says 100 mg, so 7% less.
Tested on
Lot
AK25-01
See the certificate ↓

Not checked on Krause Analytical's portal

This certificate carries no lookup code. Krause Analytical has a public portal, so a report with a code can be looked up there.

Krause Analytical's site says: “Please attach the original CoA from your vendor here. Screenshots or transposed documents cannot be validated.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.07%How much of what's in the vial is the target compound
Amount in the vial93.4 mglabel says 100 mg · 7% lessWhether you get the amount on the label
EndotoxinNDIs it safe to inject? Checks for bacterial toxins
ContainerBlue liquid in clear glass vial with copper/bronze cap and label reading "AK-Cu AK25"
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 100 mg · Lab measured 93.4 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 7% less means in a syringe

93% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 23.4 mg using the measured mass, against 25 mg on the label — 7% less.

Certificate of analysis

Original document
Issued by Krause Analytical · Nov 10, 2025 · Batch AK25-01

About this test

How this certificate was checked

Report numberAK25-01
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validKrause Analytical's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Regenerative Research Peptides' Trust Score until Nov 10, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Apr 30, 2026
Summary

Independent HPLC purity analysis of AHK-Cu from Regenerative Research Peptides, performed by Krause Analytical on November 10, 2025. Reported purity: 99.07%. Net content: 93.4 mg against 100 mg labeled (93% of label). Endotoxins: ND. Batch AK25-01. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

7 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.