AHK-Cu 100mg lab test from Nova Labs, July 2026
Janoshik Labs tested AHK-Cu 100mg from Nova Labs on Jul 8, 2026. It measured 99.23% purity and 90.17 mg against 100 mg on the label.
- In the vial
- 90.17 mgThe label says 100 mg, so 10% less.
- Tested by
- Janoshik Labs
- Tested on
Confirmed on Janoshik Labs' portal · checked Jul 8, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
URCB27N1FGIASample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 35 AHK-Cu lab tests →AHK-Cu pricesNova Labs reviews and all 28 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.23% | How much of what's in the vial is the target compound |
| Amount in the vial | 90.17 mglabel says 100 mg · 10% less | Whether you get the amount on the label |
| Container | Transparent silver cap vial | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 100 mg · Lab measured 90.17 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 10% less means in a syringe
90% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 22.5 mg using the measured mass, against 25 mg on the label — 10% less.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 193399 |
|---|---|
| On the lab's portal | ✓ Confirmed Sep 9, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Nova Labs' Trust Score until Jul 8, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 01 · Peptigrity team · filed Sep 9, 2026 |
Independent HPLC purity analysis of AHK-Cu from Nova Labs, performed by Janoshik Labs on July 8, 2026. Reported purity: 99.23%. Net content: 90.17 mg against 100 mg labeled (90% of label). Batch Transparent Silver cap. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 33 other AHK-Cu tests on Peptigrity have a typical purity of 99.63%. This one is 99.23%.